Sample analysis procedure for paddy, including receipt, assessment, moisture determination, detailed analysis, and documentation.
To obtain a representative sample, collect portions from all sides of the paddy heap or from multiple bags using a sampling probe. Thoroughly mix all collected portions. Next, use a Boerner Divider to reduce the sample quantity to 500 grams per packet. Finally, prepare two or three of these representative sample packets and submit them for detailed analysis. For accurate processing, tracking, and timely action, a mandatory delivery or accompanying slip with all necessary details is required.
Receive the sample (~500 gm) and verify the details slip.
Record all relevant sample information.
Transfer the sample from the bag onto the tray and spread it evenly.
Assess the color and sensory attributes of the sample.
Divide the sample in the tray into four equal portions.
Assess the moisture content of each of the four segments and calculate the average.
Record the resulting average moisture content in the register.
Transfer two of the portions into separate enamel plates for detailed examination.
From the first enamel plate, measure and separate 100 grams. Document the observations after analyzing the following refractions in this portion: Foreign Matter (FM), Discoloration (Dis), Damaged Weeviled/Sprouted (DWS), and Immature /Shrunken /Shriveled (ISS).
Use the sample in the second plate for the Thousand Grain Weight (TGW). Save time by utilizing a grain counting machine. Repeat measurement and record the average.
Record all findings from the analysis in the designated format.
After analysis, repack the remaining materials from the tray and plates into the original cover and attach the details slip.
Store the analyzed samples separately for potential future reference.
Note: Meticulously follow the procedures outlined above, then utilize the Fairness calculator.